HLL T8 LED LAMP (EXTERNAL DRIVER)
PREMIUM SERIES
Features
- Safe and riskless DC operation, max 45VDC input
- With an external constant current transformer
- Low temperature rise
- Nichia LEDs with 50K hours life at L70, with IES LM-80-08 certified
- High number of switching cycles
- Aluminum PCB for better LED heat dissipation
- Using segmenting LED binnings for narrower CCT range
- System efficacy up to 100 lm/w
- Suitable for emergency lighting kit
- Aluminum heat sink with polycarbonate tube
- Extremely break resistant
- Complies with RoHS directive
- Dimmable via optional 1-10V or DMX-512 drivers
Characteristics
Rated supply voltage | 45VDC (max) |
Start time | < 0.5 Sec |
Lamp switching cycles | >200,000 |
Ambient temperature (ta) | -20 … +50°C |
Driver efficiency | up to 87% |
Power factor | ≥95% |
THD | <15% |
Protection | IP20 |
CRI | >80 |
Beam angle | 150° |
Lumen maintenance (L70) | >50K Hrs |
※ Data tested with HLT Driver
Years Warranty
Hours of LED Life
Lumen / Watt
LED Chips
The series incorporates best of best Nichia LEDs from Japan. The LEDs have the longest LED life and the best performance in the industry. They are IES lM-80-2008 (Measuring Lumen Maintenance of LED Light Sources) certified for the best reliability and performance. For eye safety, the LEDs are also IEC 62471:2008 (Photobiological Safety of Lamps and Lamp Systems) certificated.
LED Drivers
- HLT Drivers are constant current driver for non-dimming applications. The drivers are characterised by very high reliability and performance.
- HLT Flicker-Free Drivers are flicker-free constant current driver for non-dimming applications. The drivers are characterised by very high reliability and performance.
- For dimming applications, HLT 1-10 V Dimming Drivers can be selected. The drivers support industrial standard 1-10V dimming interface.
- To have emergency lighting function, HEL emergency lighting units are used for both AC and DC battery supplies. Five steps dimming is provided via the infrared remote controller. DMX-512 dimming driver is also available for the downlight.
LED Tube Dimensions
Model | Diameter (mm) | Length L (mm) |
---|---|---|
HLL-24-8xx | 28 | 603 |
HLL-36-8xx | 28 | 908 |
HLL-48-8xx | 28 | 1213 |
HLL-60-8xx | 28 | 1513 |
Compliances
EN 62776:2014 Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications
EN 62471:2008 Photobiological safety of lamps and lamp systems
Ordering Information
Model | Circuit Power (W) |
Iin (mA) |
CCT (K) |
Lumen (lm) |
Efficacy (lm/W) |
LED Driver |
---|---|---|---|---|---|---|
HLL-24-830 | 10.0 | 225 | 3000 | 900 | 90 | HLT-225-42 |
HLL-36-830 | 15.0 | 350 | 3000 | 1350 | 90 | HLT-350-42 |
HLL-48-830 | 19.5 | 450 | 3000 | 1800 | 92 | HLT-450-42 |
HLL-60-830 | 23.5 | 550 | 3000 | 2250 | 96 | HLT-550-42 |
HLL-24-840 | 10.0 | 225 | 4000 | 1000 | 100 | HLT-225-42 |
HLL-36-840 | 15.0 | 350 | 4000 | 1500 | 100 | HLT-350-42 |
HLL-48-840 | 19.5 | 450 | 4000 | 2000 | 103 | HLT-450-42 |
HLL-60-840 | 23.5 | 550 | 4000 | 2500 | 106 | HLT-550-42 |
HLL-24-865 | 10.0 | 225 | 6500 | 1000 | 100 | HLT-225-42 |
HLL-36-865 | 15.0 | 350 | 6500 | 1500 | 100 | HLT-350-42 |
HLL-48-865 | 19.5 | 450 | 6500 | 2000 | 103 | HLT-450-42 |
HLL-60-865 | 23.5 | 550 | 6500 | 2500 | 106 | HLT-550-42 |
Model | Circuit Power (W) |
Iin (mA) |
CCT (K) |
Lumen (lm) |
Efficacy (lm/W) |
LED Driver |
---|---|---|---|---|---|---|
HLL-24-830 | 10.0 | 225 | 3000 | 900 | 90 | HLT-225-42F |
HLL-36-830 | 15.0 | 350 | 3000 | 1350 | 90 | HLT-350-42F |
HLL-48-830 | 19.5 | 450 | 3000 | 1800 | 92 | HLT-450-42F |
HLL-60-830 | 23.5 | 550 | 3000 | 2250 | 96 | HLT-550-42F |
HLL-24-840 | 10.0 | 225 | 4000 | 1000 | 100 | HLT-225-42F |
HLL-36-840 | 15.0 | 350 | 4000 | 1500 | 100 | HLT-350-42F |
HLL-48-840 | 19.5 | 450 | 4000 | 2000 | 103 | HLT-450-42F |
HLL-60-840 | 23.5 | 550 | 4000 | 2500 | 106 | HLT-550-42F |
HLL-24-865 | 10.0 | 225 | 6500 | 1000 | 100 | HLT-225-42F |
HLL-36-865 | 15.0 | 350 | 6500 | 1500 | 100 | HLT-350-42F |
HLL-48-865 | 19.5 | 450 | 6500 | 2000 | 103 | HLT-450-42F |
HLL-60-865 | 23.5 | 550 | 6500 | 2500 | 106 | HLT-550-42F |
Model | Circuit Power (W) |
Iin (mA) |
CCT (K) |
Lumen (lm) |
Efficacy (lm/W) |
LED Driver |
---|---|---|---|---|---|---|
HLL-24-830 | 10.0 | 225 | 3000 | 900 | 90 | HLT-225-42A |
HLL-36-830 | 15.0 | 350 | 3000 | 1350 | 90 | HLT-350-42A |
HLL-48-830 | 19.5 | 450 | 3000 | 1800 | 92 | HLT-450-42A |
HLL-60-830 | 23.5 | 550 | 3000 | 2250 | 96 | HLT-550-42A |
HLL-24-840 | 10.0 | 225 | 4000 | 1000 | 100 | HLT-225-42A |
HLL-36-840 | 15.0 | 350 | 4000 | 1500 | 100 | HLT-350-42A |
HLL-48-840 | 19.5 | 450 | 4000 | 2000 | 103 | HLT-450-42A |
HLL-60-840 | 23.5 | 550 | 4000 | 2500 | 106 | HLT-550-42A |
HLL-24-865 | 10.0 | 225 | 6500 | 1000 | 100 | HLT-225-42A |
HLL-36-865 | 15.0 | 350 | 6500 | 1500 | 100 | HLT-350-42A |
HLL-48-865 | 19.5 | 450 | 6500 | 2000 | 103 | HLT-450-42A |
HLL-60-865 | 23.5 | 550 | 6500 | 2500 | 106 | HLT-550-42A |
Model | Circuit Power (W) |
Iin (mA) |
CCT (K) |
Lumen (lm) |
Efficacy (lm/W) |
LED Driver |
---|---|---|---|---|---|---|
HLL-24-830E※ | 10.0 | 225 | 3000 | 900 | 90 | HEL-225-48 |
HLL-36-830E※ | 15.0 | 350 | 3000 | 1350 | 90 | HEL-350-48 |
HLL-48-830E※ | 19.5 | 450 | 3000 | 1800 | 92 | HEL-450-48 |
HLL-60-830E※ | 23.5 | 550 | 3000 | 2250 | 96 | HEL-550-48 |
HLL-24-840E※ | 10.0 | 225 | 4000 | 1000 | 100 | HEL-225-48 |
HLL-36-840E※ | 15.0 | 350 | 4000 | 1500 | 100 | HEL-350-48 |
HLL-48-840E※ | 19.5 | 450 | 4000 | 2000 | 103 | HEL-450-48 |
HLL-60-840E※ | 23.5 | 550 | 4000 | 2500 | 106 | HEL-550-48 |
HLL-24-865E※ | 10.0 | 225 | 6500 | 1000 | 100 | HEL-225-48 |
HLL-36-865E※ | 15.0 | 350 | 6500 | 1500 | 100 | HEL-350-48 |
HLL-48-865E※ | 19.5 | 450 | 6500 | 2000 | 103 | HEL-450-48 |
HLL-60-865E※ | 23.5 | 550 | 6500 | 2500 | 106 | HEL-550-48 |
※ Use suffix “2” or “3” for 2-hr or 3-hr emergency lighting option