HLI T8 LED LAMP (INTEGRATED DRIVER)
STANDARD SERIES
Features
- Integrated driver with high PFC
- For direct replacement for conventional control gear circuit as per IEC 62776:2014
- Rewiring and removal of magnetic ballast are not required
- Ultra high efficient and durable control driver IC and Japanese electrolytic capacitors
- Everlight with 40K hours life at L70
- High number of switching cycles
- Aluminum PCB for better LED heat dissipation
- Using segmenting LED binnings for narrower CCT range
- System efficacy up to 120 lm/w
- Aluminum heat sink with polycarbonate tube
- Extremely break resistant
- Complies with RoHS directive
Characteristics
Rated supply voltage | 220-240 VAC ±10% |
Supply frequency | 50-60 Hz |
Start time | < 0.5 Sec |
Lamp switching cycles | >200,000 |
Ambient temperature (ta) | -20 … +50°C |
Driver efficiency | up to 87% |
Power factor | ≥95% |
THD | <15% |
Protection | IP20 |
CRI | >80 |
Beam angle | 150° |
Lumen maintenance (L70) | >40K Hrs |
%
Power Factor
%
THD
Years Warranty
Hours of LED Life
Lumen / Watt
LED Chips
They are IES lM-80-2008 (Measuring Lumen Maintenance of LED Light Sources) certified to sure the reliability and performance.
LED Drivers
The drivers are built by using high efficient control IC and long life high temperature electrolytic capacitors from Japan.
LED Tube Dimensions
Model | Diameter (mm) |
Length L (mm) |
---|---|---|
HLI-24-8xx | 28 | 603 |
HLI-36-8xx | 28 | 908 |
HLI-48-8xx | 28 | 1213 |
HLI-60-8xx | 28 | 1513 |
CCG Retrofit Instructions (as per IEC 62776)
- Switch off electricity
- Rotate the conventional lamp
- Remove the conventional lamp
- Remove the starter
- Click the LED replacement starter into the starter holder
- Insert the LED lamp into the lampholder.
- Secure the position by turning the lamp by 90°
- Switch on electricity and check for lamp starting
Direct Wiring Instructions
- Rewiring must be done by qualified electricians only
- Switch off and disconnect electricity
- Remove the fluorescent lamp
- Remove power factor correction capacitor if installed
- Rewire the luminaire as shown in the circuit diagam
- Use LED replacement starter or a fuse of 250V 2A for protection
- Insert HLI T8 LED lamp
- Mark the luminaire to indicate replacement LED lamp type
- Never insert fluorescent lamp with rewired luminaire
Compliances
EN 62776:2014 Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications
EN 62471:2008 Photobiological safety of lamps and lamp systems
EN 60155 Glow-starters for fluorescent lamps
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
Ordering Information
Model | Circuit Power (W) |
PF (%) |
THD (%) |
CCT (K) |
Lumen (lm) |
Efficacy (lm/W) |
Length (L) |
---|---|---|---|---|---|---|---|
HLI-24-830E | 9.0 | ≥92 | <15 | 3000 | 1000 | 111 | 603 |
HLI-36-830E | 13.5 | ≥95 | <15 | 3000 | 1500 | 111 | 908 |
HLI-48-830E | 18.0 | ≥95 | <15 | 3000 | 2000 | 111 | 1213 |
HLI-60-830E | 22.5 | ≥95 | <15 | 3000 | 2500 | 111 | 1513 |
HLI-24-840E | 9.0 | ≥95 | <15 | 4000 | 1080 | 120 | 603 |
HLI-36-840E | 13.5 | ≥95 | <15 | 4000 | 1620 | 120 | 908 |
HLI-48-840E | 18.0 | ≥95 | <15 | 4000 | 2160 | 120 | 1213 |
HLI-60-840E | 22.5 | ≥95 | <15 | 4000 | 2700 | 120 | 1513 |
HLI-24-865E | 9.0 | ≥95 | <15 | 6500 | 1080 | 120 | 603 |
HLI-36-865E | 13.5 | ≥95 | <15 | 6500 | 1620 | 120 | 908 |
HLI-48-865E | 18.0 | ≥95 | <15 | 6500 | 2160 | 120 | 1213 |
HLI-60-865E | 22.5 | ≥95 | <15 | 6500 | 2700 | 120 | 1513 |