EMERGENCY LIGHTING UNITS
FOR HLL T8 LED LAMPS
Features
- Micro-processor controlled self-contained emergency lighting units
- AC and DC constant current drivers in one system
- Support all Hoye HLL LED lamps
- No relay for changeover
- Safe and reliable low DC voltage changeover
- Instant changeover, no black-out time
- One bi-color LED for multiple status indications
- LED short-circuit and open-circuit protections
- Long life high temp Ni-Cd battery
- Less than 1W standby power
- Deep-discharge shutdown for battery protection
- Constant current battery charger with open-load and over-current protections
- Infrared remote control for testing and 5 steps of dimming control
- Can fit in standard battens directly
Electrical Characteristics
Rated supply voltage | 220-240 VAC (-10%, +10%) |
Supply frequency | 50-60 Hz |
Changeover time | <0.3 Sec |
Recharge time | <12 hrs |
Power factor | >0.85 |
Battery cut-off voltage | <1.0V/cell |
Ambient temp (ta) | 0 … +50°C |
Max. case temp (tc) | 70°C |
Weight | 1.2 kg |
Recharge Hours
Discharge Hours (option)
Micro-Controller Controlled Operations
The improves system reliability and makes the system smarter for the whole operations.
Remote Control
Dimensions
Compliances
EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)
EN 61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
EN 61951-1 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Portable sealed rechargeable single cells – Part 1: Nickel-cadmium
BS 5266 part 1 Emergency lighting. Code of practice for the emergency lighting of premises
EN 1838 Lighting applications. Emergency lighting
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
FSD Circular Letter No. 1/2006: PPA-104(A) 4th Rev Fire Safety Standards for Emergency Lighting
Product Models
Model | LED Lamp | Lamp Type |
Lamp Power (W) |
Battery | EBLF | Discharge Hours (W) |
---|---|---|---|---|---|---|
HEL-225-48-502 | HLL-24 | T8 G13 600mm | 9.0 | H10A10 (12V, 1Ah) | 50 | 2 |
HEL-225-48-273 | HLL-24 | T8 G13 600mm | 9.0 | H10A10 (12V, 1Ah) | 27 | 3 |
HEL-450-48-442 | HLL-48 | T8 G13 1200mm | 18.0 | H10S20F (12V, 2Ah) | 44 | 2 |
HEL-450-48-353 | HLL-48 | T8 G13 1200mm | 18.0 | H10S20F (12V, 2Ah) | 35 | 3 |