FLUORESCENT BATTENS
HFB T8
Features
- For standard T8 G13 base lamps
- Available in single and double lamp
- Options of reflectors and diffusers
- HPP ballasts as standard configuration
- HDA ballasts as 1-10V dimming option
- 2-hr or 3-hr emergency lighting option
Electrical Characteristics
See detailed information below:
HPP T8 Electronic Ballasts
HDA T8 Electronic Ballasts
HED Emergency Lighting Units
Constructions
Body | White powered coated sheet body |
Lamp holder | BJB, flame retardant grade |
Wires | UL approved, 105°C |
Terminal block | BJB, flame retardant grade |
ECGs Options
For dimming applications, HDA T8 ballasts can be selected. The ballasts support industrial standard 1-10V dimming interface.
To have emergency lighting function, a HED emergency lighting unit is connected to one of the above electronic ballasts as a whole system.
Dimensions
Compliances
EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)
EN 61347-2-3 Lamp control gear – Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
EN 61347-2-7 Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements
EN 60598-1 Luminaires. General requirements and tests
EN 60598-2-1 Luminaires. Particular requirements. Specification for fixed general purpose luminaires
EN 60598-2-22 Luminaires. Particular requirements. Luminaires for emergency lighting
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
FSD Circular Letter No. 1/2006: PPA-104(A) 4th Rev Fire Safety Standards for Emergency Lighting
Product Models
Model | Lamp Type |
Length (mm) |
---|---|---|
HFB#-118PP | T8 G13, 1x18W | 610 |
HFB#-130PP | T8 G13, 1x30W | 912 |
HFB#-136PP | T8 G13, 1x36W | 1220 |
HFB#-158PP | T8 G13, 1x58W | 1525 |
HFB#-218PP | T8 G13, 2x18W | 610 |
HFB#-230PP | T8 G13, 2x30W | 915 |
HFB#-236PP | T8 G13, 2x36W | 1220 |
HFB#-258PP | T8 G13, 2x58W | 1525 |
※ Omit “#” for standard, replace with “R” for adding reflectors, replace with “D” for adding diffusers
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “F” for optional fused terminal blocks
Model | Lamp Type |
Length (mm) |
---|---|---|
HFB#-118DA | T8 G13, 1x18W | 610 |
HFB#-130DA | T8 G13, 1x30W | 912 |
HFB#-136DA | T8 G13, 1x36W | 1220 |
HFB#-158DA | T8 G13, 1x58W | 1525 |
HFB#-218DA | T8 G13, 2x18W | 610 |
HFB#-230DA | T8 G13, 2x30W | 915 |
HFB#-236DA | T8 G13, 2x36W | 1220 |
HFB#-258DA | T8 G13, 2x58W | 1525 |
※ Omit “#” for standard, replace with “R” for adding reflectors, replace with “D” for adding diffusers
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “F” for optional fused terminal blocks