FLUORESCENT LUMINAIRES

HLA T8 T-BAR RECESSED MOUNT

Features

  • For standard T8 G13 base lamps
  • Available in single and double lamp
  • Optional reflectors and diffusers can be attached
  • HPP ballasts as standard configuration
  • HDA ballasts as 1-10V dimming option
  • 2-hr or 3-hr emergency lighting option

Electrical Characteristics

See detailed information below:
HPP T8 Electronic Ballasts
HDA T8 Electronic Ballasts
HED Emergency Lighting Units

Constructions

Body White powered coated sheet body
Lamp holder BJB, flame retardant grade
Wires UL approved, 105°C
Terminal block BJB, flame retardant grade

Types of Optics

G1 High gloss parabolic aluminium side-reflectors and high gloss parabolic cross-lamellae

G2 High gloss parabolic aluminium side-reflectors and matt mill-finish cross-lamellae

G3 High gloss parabolic aluminium side-reflectors and matt cross-lamellae

M1 Matt parabolic aluminium side-reflectors and matt mill-finish cross-lamellae

M2 Matt parabolic aluminium side-reflectors and matt cross-lamellae

M3 Matt parabolic aluminium side-reflectors and matt parabolic cross-lamellae

ECGs Options

HPP T8 ballasts are the standard ECG for non-dimming applications. The ballasts are characterised by very high reliability and performance.

For dimming applications, HDA T8 ballasts can be selected. The ballasts support industrial standard 1-10V dimming interface.

To have emergency lighting function,  a HED emergency lighting unit is connected to one of the above electronic ballasts as a whole system.

Dimensions

Compliances

EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)

EN 61347-2-3 Lamp control gear – Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps

EN 61347-2-7 Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)

EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements

EN 60598-1 Luminaires. General requirements and tests

EN 60598-2-2 Luminaires. Particular requirements. Recessed luminaires

EN 60598-2-22 Luminaires. Particular requirements. Luminaires for emergency lighting

EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)

EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

EN 61547 Equipment for general lighting purposes. EMC immunity requirements

FSD Circular Letter No. 1/2006: PPA-104(A) 4th Rev Fire Safety Standards for Emergency Lighting

Product Models

Model Lamp
Type
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-1#118PP T8 G13, 1x18W 595 295 95
HLA-1#218PP T8 G13, 2x18W 595 295 95
HLA-1#318PP T8 G13, 3x18W 595 595 95
HLA-1#418PP T8 G13, 4x18W 595 595 95
HLA-1#136PP T8 G13, 1x36W 1,195 295 95
HLA-1#236PP T8 G13, 2x36W 1,195 295 95
HLA-1#336PP T8 G13, 3x36W 1,195 595 95
HLA-1#436PP T8 G13, 4x36W 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-1#118DA T8 G13, 1x18W 595 295 95
HLA-1#218DA T8 G13, 2x18W 595 295 95
HLA-1#318DA T8 G13, 3x18W 595 595 95
HLA-1#418DA T8 G13, 4x18W 595 595 95
HLA-1#136DA T8 G13, 1x36W 1,195 295 95
HLA-1#236DA T8 G13, 2x36W 1,195 295 95
HLA-1#336DA T8 G13, 3x36W 1,195 595 95
HLA-1#436DA T8 G13, 4x36W 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-3#118PP T8 G13, 1x18W 606 302 95
HLA-3#218PP T8 G13, 2x18W 606 302 95
HLA-3#318PP T8 G13, 3x18W 606 606 95
HLA-3#418PP T8 G13, 4x18W 606 606 95
HLA-3#136PP T8 G13, 1x36W 1,216 302 95
HLA-3#236PP T8 G13, 2x36W 1,216 302 95
HLA-3#336PP T8 G13, 3x36W 1,216 606 95
HLA-3#436PP T8 G13, 4x36W 1,216 606 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-3#118DA T8 G13, 1x18W 606 302 95
HLA-3#218DA T8 G13, 2x18W 606 302 95
HLA-3#318DA T8 G13, 3x18W 606 606 95
HLA-3#418DA T8 G13, 4x18W 606 606 95
HLA-3#136DA T8 G13, 1x36W 1,216 302 95
HLA-3#236DA T8 G13, 2x36W 1,216 302 95
HLA-3#336DA T8 G13, 3x36W 1,216 606 95
HLA-3#436DA T8 G13, 4x36W 1,216 606 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “F” for optional fused terminal blocks