LED LUMINAIRES

HLL F-TYPE RECESSED MOUNT

Features

  • Long life LED
  • Power consumption is only 60% of T8 luminaires with electronic ballasts
  • Direct replacement for fluorescent luminaires
  • Low profile type for only 35mm
  • System efficacy up to 90lm/w
  • High CRI
  • 35,000 hours LED life
  • Optional 1-10V or DMX-512 dimming interface
  • LED transformers are replaceable
  • Options for 2-hour or 3-hour emergency lighting kits

Electrical Characteristics

Rated supply voltage 220-240 VAC ±10%
Lamp power 27W
Circuit power 30W
Lamp switching cycles >200,000
Ambient temperature (ta) -20 … +50°C
Driver efficiency up to 90%
Power factor ≥95%
THD <15%
Protection IP20
CRI >80
Lumen maintenance (L70) >35K Hrs

LED Drivers

  • HLT Drivers are constant current driver for non-dimming applications. The drivers are characterised by very high reliability and performance.
  • HLT Flicker-Free Drivers are flicker-free constant current driver for non-dimming applications. The drivers are characterised by very high reliability and performance.
  • For dimming applications, HLT 1-10 V Dimming Drivers can be selected. The drivers support industrial standard 1-10V dimming interface.
  • To have emergency lighting function,  HEL emergency lighting units are used for both AC and DC battery supplies. Five steps dimming is provided via the infrared remote controller. DMX-512 dimming driver is also available for the downlight.

Dimensions

Compliances

EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)
EN 61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements
EN 60598-1 Luminaires. General requirements and tests
EN 60598-2-2 Luminaires. Particular requirements. Recessed luminaires
EN 60598-2-22Luminaires. Particular requirements. Luminaires for emergency lighting
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
FSD Circular Letter No. 1/2006: PPA-104(A) 4th Rev Fire Safety Standards for Emergency Lighting

Product Models

Model CCT
(K)
Lumen
(lm)
Efficacy
(lm/W)
LED
Driver
Dimensions
L x W x H (mm)
HLL-F22-27-830 3000 2565 95 HLT-700-42 595 x 595 x 35
HLL-F22-27-840 4000 2565 95 HLT-700-42 595 x 595 x 35
HLL-F22-27-865 6500 2860 100 HLT-700-42 595 x 595 x 35
Model CCT
(K)
Lumen
(lm)
Efficacy
(lm/W)
LED
Driver
Dimensions
L x W x H (mm)
HLL-F22-27-830A 3000 2565 95 HLT-700-42A 595 x 595 x 35
HLL-F22-27-840A 4000 2565 95 HLT-700-42A 595 x 595 x 35
HLL-F22-27-865A 6500 2860 100 HLT-700-42A 595 x 595 x 35
Model CCT
(K)
Lumen
(lm)
Efficacy
(lm/W)
LED
Driver
Dimensions
L x W x H (mm)
HLL-F22-27-830E※ 3000 2565 95 HEL-700-42 595 x 595 x 35
HLL-F22-27-840E※ 4000 2565 95 HEL-700-42 595 x 595 x 35
HLL-F22-27-865E※ 6500 2860 100 HEL-700-42 595 x 595 x 35

※ Use suffix “2” or “3” for 2-hr or 3-hr emergency lighting option