HLC8 LED LAMP (INTEGRATED DRIVER)
PREMIUM SERIES
Features
- Integrated driver with high PFC
- For direct replacement for conventional control gear circuit as per IEC 62776:2015
- Rewiring and removal of magnetic ballast are not required
- Ultra high efficient and durable control driver IC and Japanese electrolytic capacitors
- Nichia LEDs with 50K hours life at L70, with IES LM-80-08 certified
- High number of switching cycles
- Aluminum PCB for better LED heat dissipation
- Using segmenting LED binnings for narrower CCT range
- System efficacy up to 180 lm/w
- Aluminum heat sink with polycarbonate tube
- Extremely break resistant
- Complies with RoHS directive
Characteristics
Rated supply voltage | 220-240 VAC ±10% |
Supply frequency | 50-60 Hz |
Start time | < 0.5 Sec |
Lamp switching cycles | >200,000 |
Ambient temperature (ta) | -20 … +50°C |
Driver efficiency | up to 87% |
Power factor | ≥95% |
THD | <15% |
Protection | IP20 |
CRI | >80 |
Beam angle | 150° |
Lumen maintenance (L70) | >50K Hrs |
%
Power Factor
%
THD
Years Warranty
Hours of LED Life
Lumen / Watt
LED Chips
They are IES lM-80-2008 (Measuring Lumen Maintenance of LED Light Sources) certified for the best reliability and performance.
For eye safety, the LEDs are also IEC 62471:2008 (Photobiological Safety of Lamps and Lamp Systems) certificated.
LED Tube Dimensions
Model | Diameter (mm) |
Length L (mm) |
---|---|---|
HLC8-600 | 28 | 603 |
HLC8-900 | 28 | 908 |
HLC8-1200 | 28 | 1213 |
HLC8-1500 | 28 | 1513 |
CCG Retrofit Instructions (as per IEC 62776)
- Switch off electricity
- Rotate the conventional lamp
- Remove the conventional lamp
- Remove the starter
- Click the LED replacement starter into the starter holder
- Insert the LED lamp into the lampholder.
- Secure the position by turning the lamp by 90°
- Switch on electricity and check for lamp starting
Direct Wiring Instructions
- Rewiring must be done by qualified electricians only
- Switch off and disconnect electricity
- Remove the fluorescent lamp
- Remove power factor correction capacitor if installed
- Rewire the luminaire as shown in the circuit diagam
- Use LED replacement starter or a fuse of 250V 2A for protection
- Insert HLI T8 LED lamp
- Mark the luminaire to indicate replacement LED lamp type
- Never insert fluorescent lamp with rewired luminaire
Compliances
EN 62776:2015 Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications
EN 62471:2008 Photobiological safety of lamps and lamp systems
EN 60155 Glow-starters for fluorescent lamps
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
Ordering Information
Model | Circuit Power (W) |
PF (%) |
THD (%) |
CCT (K) |
Lumen (lm) |
Efficacy (lm/W) |
Length (L) |
---|---|---|---|---|---|---|---|
HLC8-600-7-830 | 7.0 | ≥92 | <15 | 3000 | 1100 | 603 | |
HLC8-600-7-840 | 7.0 | ≥95 | <15 | 3000 | 1200 | 603 | |
HLC8-600-7-865 | 7.0 | ≥95 | <15 | 3000 | 1200 | 603 | |
HLC8-900-10-830 | 10.0 | ≥95 | <15 | 3000 | 1650 | 908 | |
HLC8-900-10-840 | 10.0 | ≥95 | <15 | 4000 | 1800 | 908 | |
HLC8-900-10-865 | 10.0 | ≥95 | <15 | 4000 | 1800 | 908 | |
HLC8-1200-14-830 | 14.0 | ≥95 | <15 | 4000 | 2300 | 1213 | |
HLC8-1200-14-840 | 14.0 | ≥95 | <15 | 4000 | 2500 | 1213 | |
HLC8-1200-14-865 | 14.0 | ≥95 | <15 | 6500 | 2500 | 1213 | |
HLC8-1500-20.5-830 | 20.5 | ≥95 | <15 | 6500 | 3400 | 1513 | |
HLC8-1500-20.5-840 | 20.5 | ≥95 | <15 | 6500 | 3700 | 1513 | |
HLC8-1500-20.5-865 | 20.5 | ≥95 | <15 | 6500 | 3700 | 1513 |