HXS Recessed Series – 400mm LED Exit Sign

IEC-62034 Automatic Test

 

Slim type

  • For recessed mounting

  • Pictogram only

IEC 62034 automatic test system

  • Commissioning Test

  • Functional Test

  • Duration Test

Mounting Plate

    • Screw mounting type

    • Simplify mounting work

    • Easy maintenance

Features

  • IEC 62034:2016 automatic test system for HK FSD requirements
  • Slim design with 4 mm bezel and 20 mm thickness
  • Nichia LEDs with 15 years life at L70
  • System power only 2 W
  • Full solid-state design — no mechanical relays
  • Constant brightness control for AC and DC operation
  • Chemistry-aware charging for LiFePO4, NiCd and NiMH
  • Precharge recovery for deeply discharged batteries
  • Thermal charge protection with automatic resume
  • Deep-discharge shutdown for battery protection
  • Isolated low-voltage test switch
  • Infrared remote for brightness control, changeover test, and Autotest
  • Dual LED system status indication (optional LCD status module)

Electrical Characteristics

Rated supply voltage 220-240 VAC (-20%, +10%)
Supply frequency 50-60 Hz
Circuit power 2.0W max
Changeover time <0.1 sec
Recharge time <6 hrs
Rated discharge time  3 hrs
Lumen Maintenance (L70) 15 years
Ambient temperature (ta) 0 ... +50°C
Max. temperature rise (Δt) <5°C
Battery type LiFePO4, NiCd/NiMH as option
Luminance 250 cd/㎡ max

IEC 62034 Automatic Test

According to HK FSD, Technical Guidance May 2021 and FSD Circular Letter No. 5/2021, PPA/104(A), 5th Revision, emergency lighting with self-contained batteries shall be inspected periodically. For automatic testing devices, it shall be designed in accordance with IEC 62034:2016 - Automatic test systems for battery powered emergency escape lighting.

Our test system will start automatically after mains supply is not interrupted for 5 days. After a random delay days for different device,  a commissioning test is started. This avoids adjacent devices testings at the same time. Monthly functional tests and annually duration test will then be repeated.

The firmware supports full IEC 62034 - ATS Type S, including the following tasks:

IEC 62034 

IEC 62034/BS EN 50172/FSD Requirements Automatic Test
Commissioning Testing
Maintenance  

a. Once every month a functional test in accordance with BS EN 50172 not longer than 10% of rated duration should be carried out.


60 sec

b. Once every twelve months a full rated duration test, should be carried out and the results should be entered in a register.

c. The luminaire should be functioning properly to maintain the stipulated lighting level and the normal power supply should be restored after the test.

d. If automatic testing devices are used, the above item a – c should be complied with.

 

Functional and Duration Tests

Functional and duration tests are two types of tests performed to ensure exit sign functionality and reliability.

  • Functional test is performed once a month to check the basic functionality. The test also checks the hardware parameters, such as various voltage and current. The test duration is 60 seconds.
  • Duration tests are performed once a year. The tests are the same as functional test but with additional battery life check with a full rated battery discharge.
  • Commissioning test is the first duration test. They are typically performed after the device has been installed and configured.

 

Test Performed Functional
Test
Duration
Test

1. System Changeover

2. Lamp voltage

3. Lamp current

4. Battery charging voltage

5. Battery charging current

6. Battery discharging voltage

7. Battery discharge time

 

Automatic Test Flowchart

Years Warranty

Hours of LED Life

Watt

IR Remote Control

The infrared remote makes maintenance easier. Adjust panel brightness, run a changeover test, and clear Autotest faults without opening the fitting.

  • Panel brightness dimming in normal operation
  • Restore default brightness
  • System changeover test (simulates the traditional test button)
  • Clear stored Autotest faults after the fault has been corrected

Status Indications

Two LED indicators provide a rich set of status indications for system status and faults. Operators can use the information to quickly identify and diagnose problems.

green-led-on-off

Normal Status

  • Charging
  • Battery charged
  • Functional test postponed
  • Duration test postponed

red-led-on-off

Fault Status

  • Lamp fault
  • Charger fault
  • Battery fault
  • Battery duration EOL

Compliances

FSD Circular Letter No. 5/2021 Fire Safety Requirements for Emergency Lighting Systems in Licensed/Registered Premises

IEC 62034:2016 Automatic test systems for battery powered emergency escape lighting

BS 5266-1:2016 Emergency lighting – Code of practice for the emergency lighting of premises

BS EN 1838:2013 Lighting applications. Emergency lighting

EN 61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

EN 62384 DC or AC supplied electronic control gear for LED modules. Performance requirements

EN 60598-1 Luminaires. General requirements and tests

EN 60598-2-22 Luminaires. Particular requirements. Luminaires for emergency lighting

EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)

EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

EN 61547 Equipment for general lighting purposes. EMC immunity requirements

Dimensions

Emergency Exit Legends

Ordering Information

Model Width (mm) Legend Illuminated Side
HXS-R4SJ 400 J Single
HXS-R4SK 400 K Single
HXS-R4SL 400 L Single
HXS-R4SM 400 M Single
HXS-R4SN 400 N Single
HXS-R4SO 400 O Single