LED EXIT SIGN
HXL PENDULUM MOUNTING
![](https://hoye.com/wp-content/uploads/2015/07/Exit-Sign-Pendulum.png)
Features
- Intelligent LED exit signs with automatic self-test
- Nichia LEDs with 50K hours life at L70, with IES LM-80-08 certified
- System power is only 2W
- Full solid-state design without mechanical part
- Constant brightness control for both AC and DC operations
- Programmable lamp flashing in emergency mode
- Less than 5°C temperature rise for the whole system
- Deep-discharge shutdown for battery protection
- Optically isolated low voltage test switch
- High efficient switching mode charger with full protections
- Pulse charge mode for full battery
- Less than 12 hours battery recharge time
- High quality light guide panels
- Optional infrared remote control for self-test, system set up and dimming
Electrical Characteristics
Rated supply voltage | 220-240 VAC (-20%, +10%) |
Supply frequency | 50-60 Hz |
Circuit power | 2.0W max |
Changeover time | <0.1 Sec |
Recharge time | <12 hrs |
Rated discharge time | 4 hrs (typical 4.5 hrs) |
Power factor | >0.8 |
Lumen Maintenance (L70) | >50K Hrs |
Discharge cut-off voltage | <1.0V/cell |
Ambient temperature (ta) | 0 … +50°C |
Max. temperature rise (Δt) | <5°C |
Battery type | NiCd |
Lumen factor | Normal mode: 100% Emergency mode: 120% |
Years Warranty
Hours of LED Life
Watt
LED Chips
They are IES lM-80-2008 (Measuring Lumen Maintenance of LED Light Sources) certified for the best reliability and performance.
For eye safety, the LEDs are also IEC 62471:2008 (Photobiological Safety of Lamps and Lamp Systems) certificated.
![](https://hoye.com/wp-content/uploads/2015/07/nichia.png)
![](https://hoye.com/wp-content/uploads/2015/07/MCU.png)
Micro-Controller Controlled Operations
The improves system reliability and makes the system smarter for the whole operations.
Self-test
Charger
LED lamp
System changeover
Battery voltage
Battery discharge
Once fault is found, the red LED indicator will flash with different patterns for various error types.
![](https://hoye.com/wp-content/uploads/2015/07/Selftet.png)
![](https://hoye.com/wp-content/uploads/2015/07/Remote-Control.png)
IR Remote Control
The infrared remote control makes maintenance easier than ever. It can be used to set the LED exit sign system settings and self-test functions.
Panel brightness dimming control in normal operation
Flashing model in emergency mode
System changeover test (simulate traditional test button)
On-demand self-test
![](https://hoye.com/wp-content/uploads/2015/07/LGP.jpg)
Light Guide Panel
Light guide panel is characterised by high uniformity of light and efficiency.
Dimensions
![](https://hoye.com/wp-content/uploads/2015/07/HXL-Pendulum-Dimension.png)
![](https://hoye.com/wp-content/uploads/2015/07/assessment-icon-ffcabac7ba68e5fc8f7e0a514921b689.png)
Compliances
FSD Circular Letter No. 5/2021 Requirements for Self-contained Luminaires Emergency Lighting Systems [PPA/104(A) (5th Revision)
BS 5266-1:2016 Emergency lighting – Code of practice for the emergency lighting of premises
BS EN 1838:2013 Lighting applications. Emergency lighting
EN 61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
EN 62384 DC or AC supplied electronic control gear for LED modules. Performance requirements
EN 60598-1 Luminaires. General requirements and tests
EN 60598-2-22 Luminaires. Particular requirements. Luminaires for emergency lighting
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
Emergency Exit Legends
![](https://hoye.com/wp-content/uploads/2015/07/Exit-Sign-Legends.png)
Product Models
Model | Panel Width (mm) |
Illuminated Side |
---|---|---|
HXL-P4S# | 400 | Single |
HXL-P4D# | 400 | Double |
HXL-P6S# | 600 | Single |
HXL-P6D# | 600 | Double |
※ Replace “#” for emergency exit legend codes above.