LED LUMINAIRES

HLA T8 CLIP-IN MOUNT

 

Features

  • For standard T8 G13 base lamps
  • Available in single and double lamp
  • Optional reflectors and diffusers can be attached
  • HPP ballasts as standard configuration
  • HDA ballasts as 1-10V dimming option
  • Emergency lighting options of 2 hrs or 3 hrs types

Electrical Characteristics

※  See individual LED lamps for detail information.

Constructions

Body White powered coated sheet body
Lamp holder BJB, flame retardant grade
Wires UL approved, 105°C
Terminal block BJB, flame retardant grade

Types of Optics

G1 High gloss parabolic aluminium side-reflectors and high gloss parabolic cross-lamellae

G2 High gloss parabolic aluminium side-reflectors and matt mill-finish cross-lamellae

G3 High gloss parabolic aluminium side-reflectors and matt cross-lamellae

M1 Matt parabolic aluminium side-reflectors and matt mill-finish cross-lamellae

M2 Matt parabolic aluminium side-reflectors and matt cross-lamellae

M3 Matt parabolic aluminium side-reflectors and matt parabolic cross-lamellae

LED Drivers

HLT Drivers are used for non-dimming applications. The drivers are characterised by very high reliability and performance.

For dimming applications, HLT 1-10 V Dimming Drivers can be selected. The drivers support industrial standard 1-10V dimming interface.

To have emergency lighting function,  HEL emergency lighting units are used for both AC and DC battery supplies. Five steps dimming is provided via the infrared remote controller. DMX-512 dimming driver is also available for the downlight.

Dimensions

Compliances

EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)

EN 61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements

EN 60598-1 Luminaires. General requirements and tests

EN 60598-2-2 Luminaires. Particular requirements. Recessed luminaires

EN 60598-2-22 Luminaires. Particular requirements. Luminaires for emergency lighting

EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)

EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

EN 61547 Equipment for general lighting purposes. EMC immunity requirements

FSD Circular Letter No. 1/2006: PPA-104(A) 4th Rev Fire Safety Standards for Emergency Lighting

Product Models

Model Lamp
Type
Lamp
Count
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-5#12LS T8 G13 600mm 1 595 295 95
HLA-5#22LS T8 G13 600mm 2 595 295 95
HLA-5#32LS T8 G13 600mm 3 595 595 95
HLA-5#42LS T8 G13 600mm 4 595 595 95
HLA-5#14LS T8 G13 1200mm 1 1,195 295 95
HLA-5#24LS T8 G13 1200mm 2 1,195 295 95
HLA-5#34LS T8 G13 1200mm 3 1,195 595 95
HLA-5#44LS T8 G13 1200mm 4 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “A” for 1-10V dimming
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Lamp
Count
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-5#12LP T8 G13 600mm 1 595 295 95
HLA-5#22LP T8 G13 600mm 2 595 295 95
HLA-5#32LP T8 G13 600mm 3 595 595 95
HLA-5#42LP T8 G13 600mm 4 595 595 95
HLA-5#14LP T8 G13 1200mm 1 1,195 295 95
HLA-5#24LP T8 G13 1200mm 2 1,195 295 95
HLA-5#34LP T8 G13 1200mm 3 1,195 595 95
HLA-5#44LP T8 G13 1200mm 4 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “A” for 1-10V dimming
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Lamp
Count
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-5#12IV T8 G13 600mm 1 595 295 95
HLA-5#22IV T8 G13 600mm 2 595 295 95
HLA-5#32IV T8 G13 600mm 3 595 595 95
HLA-5#42IV T8 G13 600mm 4 595 595 95
HLA-5#14IV T8 G13 1200mm 1 1,195 295 95
HLA-5#24IV T8 G13 1200mm 2 1,195 295 95
HLA-5#34IV T8 G13 1200mm 3 1,195 595 95
HLA-5#44IV T8 G13 1200mm 4 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Lamp
Count
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-5#12IS T8 G13 600mm 1 595 295 95
HLA-5#22IS T8 G13 600mm 2 595 295 95
HLA-5#32IS T8 G13 600mm 3 595 595 95
HLA-5#42IS T8 G13 600mm 4 595 595 95
HLA-5#14IS T8 G13 1200mm 1 1,195 295 95
HLA-5#24IS T8 G13 1200mm 2 1,195 295 95
HLA-5#34IS T8 G13 1200mm 3 1,195 595 95
HLA-5#44IS T8 G13 1200mm 4 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “F” for optional fused terminal blocks

Model Lamp
Type
Lamp
Count
Length
L (mm)
Width
W (mm)
Height
H (mm)
HLA-5#12IP T8 G13 600mm 1 595 295 95
HLA-5#22IP T8 G13 600mm 2 595 295 95
HLA-5#32IP T8 G13 600mm 3 595 595 95
HLA-5#42IP T8 G13 600mm 4 595 595 95
HLA-5#14IP T8 G13 1200mm 1 1,195 295 95
HLA-5#24IP T8 G13 1200mm 2 1,195 295 95
HLA-5#34IP T8 G13 1200mm 3 1,195 595 95
HLA-5#44IP T8 G13 1200mm 4 1,195 595 95

※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “F” for optional fused terminal blocks