LED LUMINAIRES
HLA T8 CLIP-IN MOUNT
Features
- For standard T8 G13 base lamps
- Available in single and double lamp
- Optional reflectors and diffusers can be attached
- HPP ballasts as standard configuration
- HDA ballasts as 1-10V dimming option
- Emergency lighting options of 2 hrs or 3 hrs types
Electrical Characteristics
※ See individual LED lamps for detail information.
Constructions
Body | White powered coated sheet body |
Lamp holder | BJB, flame retardant grade |
Wires | UL approved, 105°C |
Terminal block | BJB, flame retardant grade |
Types of Optics
G1 High gloss parabolic aluminium side-reflectors and high gloss parabolic cross-lamellae
G2 High gloss parabolic aluminium side-reflectors and matt mill-finish cross-lamellae
G3 High gloss parabolic aluminium side-reflectors and matt cross-lamellae
M1 Matt parabolic aluminium side-reflectors and matt mill-finish cross-lamellae
M2 Matt parabolic aluminium side-reflectors and matt cross-lamellae
M3 Matt parabolic aluminium side-reflectors and matt parabolic cross-lamellae
LED Drivers
HLT Drivers are used for non-dimming applications. The drivers are characterised by very high reliability and performance.
For dimming applications, HLT 1-10 V Dimming Drivers can be selected. The drivers support industrial standard 1-10V dimming interface.
To have emergency lighting function, HEL emergency lighting units are used for both AC and DC battery supplies. Five steps dimming is provided via the infrared remote controller. DMX-512 dimming driver is also available for the downlight.
Dimensions
Compliances
EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)
EN 61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements
EN 60598-1 Luminaires. General requirements and tests
EN 60598-2-2 Luminaires. Particular requirements. Recessed luminaires
EN 60598-2-22 Luminaires. Particular requirements. Luminaires for emergency lighting
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC). Limits. Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
FSD Circular Letter No. 1/2006: PPA-104(A) 4th Rev Fire Safety Standards for Emergency Lighting
Product Models
Model | Lamp Type |
Lamp Count |
Length L (mm) |
Width W (mm) |
Height H (mm) |
---|---|---|---|---|---|
HLA-5#12LS | T8 G13 600mm | 1 | 595 | 295 | 95 |
HLA-5#22LS | T8 G13 600mm | 2 | 595 | 295 | 95 |
HLA-5#32LS | T8 G13 600mm | 3 | 595 | 595 | 95 |
HLA-5#42LS | T8 G13 600mm | 4 | 595 | 595 | 95 |
HLA-5#14LS | T8 G13 1200mm | 1 | 1,195 | 295 | 95 |
HLA-5#24LS | T8 G13 1200mm | 2 | 1,195 | 295 | 95 |
HLA-5#34LS | T8 G13 1200mm | 3 | 1,195 | 595 | 95 |
HLA-5#44LS | T8 G13 1200mm | 4 | 1,195 | 595 | 95 |
※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “A” for 1-10V dimming
※ Add suffix “F” for optional fused terminal blocks
Model | Lamp Type |
Lamp Count |
Length L (mm) |
Width W (mm) |
Height H (mm) |
---|---|---|---|---|---|
HLA-5#12LP | T8 G13 600mm | 1 | 595 | 295 | 95 |
HLA-5#22LP | T8 G13 600mm | 2 | 595 | 295 | 95 |
HLA-5#32LP | T8 G13 600mm | 3 | 595 | 595 | 95 |
HLA-5#42LP | T8 G13 600mm | 4 | 595 | 595 | 95 |
HLA-5#14LP | T8 G13 1200mm | 1 | 1,195 | 295 | 95 |
HLA-5#24LP | T8 G13 1200mm | 2 | 1,195 | 295 | 95 |
HLA-5#34LP | T8 G13 1200mm | 3 | 1,195 | 595 | 95 |
HLA-5#44LP | T8 G13 1200mm | 4 | 1,195 | 595 | 95 |
※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “E2” or “E3” for 2-hr or 3-hr emergency lighting option
※ Add suffix “A” for 1-10V dimming
※ Add suffix “F” for optional fused terminal blocks
Model | Lamp Type |
Lamp Count |
Length L (mm) |
Width W (mm) |
Height H (mm) |
---|---|---|---|---|---|
HLA-5#12IV | T8 G13 600mm | 1 | 595 | 295 | 95 |
HLA-5#22IV | T8 G13 600mm | 2 | 595 | 295 | 95 |
HLA-5#32IV | T8 G13 600mm | 3 | 595 | 595 | 95 |
HLA-5#42IV | T8 G13 600mm | 4 | 595 | 595 | 95 |
HLA-5#14IV | T8 G13 1200mm | 1 | 1,195 | 295 | 95 |
HLA-5#24IV | T8 G13 1200mm | 2 | 1,195 | 295 | 95 |
HLA-5#34IV | T8 G13 1200mm | 3 | 1,195 | 595 | 95 |
HLA-5#44IV | T8 G13 1200mm | 4 | 1,195 | 595 | 95 |
※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “F” for optional fused terminal blocks
Model | Lamp Type |
Lamp Count |
Length L (mm) |
Width W (mm) |
Height H (mm) |
---|---|---|---|---|---|
HLA-5#12IS | T8 G13 600mm | 1 | 595 | 295 | 95 |
HLA-5#22IS | T8 G13 600mm | 2 | 595 | 295 | 95 |
HLA-5#32IS | T8 G13 600mm | 3 | 595 | 595 | 95 |
HLA-5#42IS | T8 G13 600mm | 4 | 595 | 595 | 95 |
HLA-5#14IS | T8 G13 1200mm | 1 | 1,195 | 295 | 95 |
HLA-5#24IS | T8 G13 1200mm | 2 | 1,195 | 295 | 95 |
HLA-5#34IS | T8 G13 1200mm | 3 | 1,195 | 595 | 95 |
HLA-5#44IS | T8 G13 1200mm | 4 | 1,195 | 595 | 95 |
※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “F” for optional fused terminal blocks
Model | Lamp Type |
Lamp Count |
Length L (mm) |
Width W (mm) |
Height H (mm) |
---|---|---|---|---|---|
HLA-5#12IP | T8 G13 600mm | 1 | 595 | 295 | 95 |
HLA-5#22IP | T8 G13 600mm | 2 | 595 | 295 | 95 |
HLA-5#32IP | T8 G13 600mm | 3 | 595 | 595 | 95 |
HLA-5#42IP | T8 G13 600mm | 4 | 595 | 595 | 95 |
HLA-5#14IP | T8 G13 1200mm | 1 | 1,195 | 295 | 95 |
HLA-5#24IP | T8 G13 1200mm | 2 | 1,195 | 295 | 95 |
HLA-5#34IP | T8 G13 1200mm | 3 | 1,195 | 595 | 95 |
HLA-5#44IP | T8 G13 1200mm | 4 | 1,195 | 595 | 95 |
※ Replace “#” with “G1”, “G2”, “G3”, “M1”, “M2” or “M3” for required optics
※ Add suffix “F” for optional fused terminal blocks