HDA T5 HE ELECTRONIC BALLASTS
Features
- 1-10VDC dimming interface
- 3-100% dimming range
- Programmed start with accurate frequency control
- Enhanced filament heating cut off technology
- Lamp power stabilization and anti-striation control for eliminating temperature effect
- Active power factor correction
- Constant light output; independent of mains voltage (156-265VAC)
- Compatible with infrared control systems
- Energy efficiency index (EEI) = A1
- Over-voltage protection for 320VAC, 1 hour
- Ballast over-current protection
- Defective lamp and EOL protections
- Automatic restart by lamp exchange
- No shutdown delay for fault reset
Electrical Characteristics
Rated supply voltage | 220 VAC ±10% |
Supply frequency | 50-60 Hz |
Preheat time | 0.9 Sec |
Lumen factor | 100% |
Lamp current crest factor | < 1.5 |
Ballast operating frequency | >42 KHz |
Operation life | 90,000 Hrs |
Lamp switching cycles | 200,000 |
Ambient temperature (ta) | -20 … +50°C |
%
Power Factor
%
THD
Years Warranty
Hours of Life
Active Power Factor Correction
With the internal active harmonic filter, power factor of Hoye electronic ballasts is higher than 98% and total harmonic distortion is reduced to less than 10%, which is far beyond the limits of IEC 61000-3-2.
Electromagnetic Interference
The electromagnetic interference of Hoye electronic ballasts is further suppressed with the improved circuit design technologies. EMC performance is superior to most other products in the market.
Input Regulation
With the internal voltage regulation circuit, the luminous flux is unaffected by mains voltage. It provides a comfortable and stable light source for the environment.
Dimensions & Wiring
Compliances
EN 61347-2-1 Lamp controlgear. Particular requirements for starting devices (other than glow starters)
EN 61347-2-3 Lamp control gear – Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
EN 60929 AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61547 Equipment for general lighting purposes. EMC immunity requirements
Product Models
Model | Lamp Type |
Circuit Power (W) |
Lamp Power (W) |
PF (%) |
THD (%) |
tc (°C) |
Weight (g) |
---|---|---|---|---|---|---|---|
HDA-114 | 1x14W | 17.0 | 1×13.7 | 98 | 9.5 | 65 | 275 |
HDA-121 | 1x21W | 24.0 | 1×20.7 | 98 | 9.5 | 65 | 275 |
HDA-128 | 1x28W | 31.5 | 1×27.8 | 98 | 9.5 | 65 | 280 |
HDA-135 | 1x35W | 39.0 | 1×34.7 | 98 | 8.5 | 65 | 280 |
HDA-214 | 2x14W | 33.0 | 2×13.7 | 98 | 9.5 | 65 | 360 |
HDA-221 | 2x21W | 47.0 | 2×20.7 | 98 | 9.0 | 70 | 360 |
HDA-228 | 2x28W | 62.0 | 2×27.8 | 98 | 8.5 | 70 | 360 |
HDA-235 | 2x35W | 77.0 | 2×34.7 | 99 | 8.0 | 70 | 375 |